Current news
Steel structure tower is mainly design for human accessibility to perform work. Chimney's tower for Utility buildings for factory require accessibility according to the new requirement by Malaysian Government for the DOE to monitor carbon emission release for PEAR safety purposes.
Some structure such as telecommunication towers are different which the human accessibility is nearly negligible.
PEAR, people, environment, asset and reputation are the required element to be taken care for a company to sustain in a green environmental policy.
Therefore, a monitoring route shall be designed for the purpose and steel structure will play part for the high rise exhaust gas release area.
Here, the structure engineering must follow the local and international standard such as BS 14122. This standard is to cater an appropriate design with highest safety standard.
The design shall be from top to bottom and the maximum load can be calculated by using software or manual in order to determine the footing size and locations.
The size, angle, displacement of stair case or cat ladder are well stated in the standards. The company uses the international codes for highest standard design and reputable software to design in accordingly to client needs.
Safwan.S 2022
Sewerage system is very important as it helps people to transport the wastes away from their places. Therefore, it must be functioning well because improper of sewerage system will lead to pollution and contamination to effect surrounding and health.
The standard code of practice fro sewerage design in Malaysia (MS 1228:1991) was adopted from British Standard BS 8005:1987.
There are 2 main types of sewerage system in Malaysia, a public sewage treatment plant (STP) or individual septic tank. Currently Indah Water Konsortium (IWK) is responsible to provide service and maintenance to public STP and all underground pipes.
The sewage pipe must fall on a slope for wastewater flow of 0.8m/s velocity and not more than 4m/s.( MS1228:1991)
In IWK standard of practise, another design parameter is Population Equivalent (PE) to calculate flowrate. Usually it account for 5 PE /dwelling and it has different standard for commercial area.
Recently in 2021, IWK has include additional requirements for the an enclosed STP must be built 10 meters from the nearest dwelling and 10 meters from the next lot of land. Any open type STP will require further distance in order to avoid bad odor to nearest dwelling and public area. Any usage of odor remover is an assistant to reduce bad smell to surrounding area.
The latest requirement by IWK also will only allow pipe and manhole to be designed in front of the dwelling area and IWK is no longer supporting from back alley/road area.
Safwan.S 2022